[MC1050] - SELECTOR

DESCRIPTION


The MC1050 checks if only one of the three inputs is high. If more than one input is high, all three outputs are low.


SIGN PARAMETERS


No signparameters.


INPUTS


  • #1 : Input A
  • #2 : Input B
  • #3 : Input C


OUTPUTS


  • #1 : Output A - goes high if: A is high, B & C are low
  • #2 : Output B - goes high if: B is high, A & C are low
  • #3 : Output C - goes high if: C is high, A & B are low